Maximum measurement error
Volumetric flow rate:
– ± 0.5 % or ± 0.0.02% ofs for 0.5 to 10 m/s (1.6 to 33 ft/s)
– ± 0.07 % ofs for flow velocity < 0.5 m/s (1.64 ft/s) -
Measuring range
0.025 … 5 m/s (0.02 … 16.4 ft/s)
0 … 6360 dm3/min (0 … 1680 gal/min) -
Process temperature
0 … 150° (17.8 … 302 °F)
-
Pressure field
PN 25 / ASME Cl. 150
-
Wetted Parts Materials
Measuring tube: 1.4301 (F304)
Process connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1.4306 (F304L); 1.4307 (F304L); A105
Proline Prosonic Flow E 100 Ultrasonic Flow Meter
Category: ENDRESS +HAUSER
Measuring demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. The Prosonic Flow E 100 provides accurate and cost-effective bidirectional flow measurement in all industries. With integrated temperature measurement, the Prosonic Flow E 100 is a multivariable flow meter that can offer your plant considerable added value. Heartbeat Technology enables measurement reliability and allows extended recalibration cycles.