Maximum measurement error
Volumetric flow (standard): ±0.5 % or ± 1 mm/s (0.04 in/s)
Volumetric flow (optional): ±0.2 % or ± 2 mm/s (0.08 in/s), Flat Spec. -
Measuring range
From 0.5 m3/h to 263000 m3/h (from 2.5 g/min to 1665 Mgal/d)
-
Process temperature
Hard rubber coating: 0 to +80 °C (+32 to +176 °F)
Polyurethane coating material: -20 to +50 °C (-4 to +122 °F)
PTFE coating material: from -20 to +90 °C (-4 to +194 °F) -
Pressure field
PN 40, class 300, 20K
-
Wetted Parts Materials
Coating: Polyurethane; Hard rubber, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Proline Promag W 300 Electromagnetic flow meter
Category: ENDRESS +HAUSER
The premium device for measuring drinking water and wastewater Promag W 300 is designed for reliable use in hazardous areas and under harsh conditions. The compact transmitter offers high operation and system integration flexibility: access from one side, a separate display, and improved connectivity options. Heartbeat Technology enables measurement reliability and compliance verification