Maximum measurement error
Volumetric flow rate (standard):
– ±1.5 % vi for 3 … 30 m/s (9.84 … 98.4 ft/s)
– ±3 % vi for 1 … 3 m/s (3.28 . .. 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % vfs for 0.3 … 1 m/s (0.98 … 3.28 ft/s)
‐ ±1.5 % vi for 1 … 30 m/s (3.28 … 98.4 ft/s) -
Measuring range
Standard: 1 … 30 m/s (3.28 … 98.4 ft/s)
Option: 0.3 … 30 m/s (0.98 … 98.4 ft/s) -
Process temperature
0 … +80 °C (+32 … +176 °F)
-
Pressure field
11 bar a (159 psi a)
-
Wetted Parts Materials
Sensor: 1.4404 / 1.4435 (316L)
Transducer: HNBR
Temperature sensor (optional): AFM 34
Proline Prosonic Flow B 200 Ultrasonic Flowmeter
Category: ENDRESS +HAUSER
Prosonic Flow B 200 is designed for the production of biogas and digester gas. It measures the volume flow of wet biogas, and digester gas, even under fluctuating process conditions. With integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of the gas flow and the gas quality. Heartbeat Technology ensures safety at all times.